A wall-mounted chlorine dioxide solution generator described in the manufacturer’s May 2021 manual.

Manufacturer specifications

Nominal production: 27–33 g/h. Output solution: 100 mg/L ±15% or 200 mg/L ±15%. Dimensions: 345 × 118 × 460 mm. Supply: DC 12 V. Rated power: 48 W. Stated inlet pressure: 0.1–0.4 MPa; operating temperature: 5–45 °C.

System features

The manual describes metered reagent supply, flow feedback, concentration monitoring and a low-reagent alarm, with a 4.5-inch display.

Intended use

The manufacturer describes surface-disinfection applications. Output concentration is a generator specification and must not be confused with an appropriate concentration for every surface, organism or environment.

Material and operating limits

The supplied manual excludes metal objects because the solution is corrosive to metals, and limits continuous equipment operation to two hours. Installation and use require the full manufacturer instructions.

Source limits

These are manufacturer specifications transcribed from the supplied manual, not independent performance measurements or evidence of European product authorisation.